MC1 V3 Installation & Programming page 3 / 9
Desired Change LED: on blink blink off
Turn off all “A” intermediate stops (factory default)
13
S+7+7 O # C 10 O ALL S
Enable “Intermediate Stop A” on the main channel
5
S+7+7 O # C 10 O 1 S
Enable “Int. Stop A” on 1
st
group channel
5
S+7+7 O # C 10 O 2 S
Enable “Int. Stop A” on 2
nd
group channel
5
S+7+7 O # C 10 O 3 S
Enable “Int. Stop A” on 3
rd
group channel
5
S+7+7 O # C 10 O 4 S
Enable “Int. Stop A” on 4
th
group channel
5
S+7+7 O # C 10 O 5 S
Enable “Int. Stop A” on 5
th
group channel
5
S+7+7 O # C 10 O 6 S
Enable “Int. Stop A” on 6
th
group channel
5
S+7+7 O # C 10 O 14 S
Enable “Int. Stop A” on the ALL channel
5
S+7+7 O # C 10 O 7 S
Enable “Int. Stop A” on Manual Switches
5
S+7+7 O # C 10 O 8 S
Intermediate Stops highest accuracy
7 8
S+7+7 O # C 10 O 9 S
Calibrate the travel times
6 11
S+7+7 O # C 10 O 10
6
Reference the open limit instead of close
8 11
S+7+7 O # C 10 O 11 S
“Intermediate Stop A Open Button”
Set to 10x+y percent of travel time away from reference end
min = 0 0 (at ref.), max = 9 9 (opposite limit) use O10 for 0
Nudge this stop 1/40
th
second away from reference
Nudge this stop 1/40
th
second towards reference
S+7+7
S+7+7
S+7+7
O #
O #
O #
C 11
C 11
C 11
Ox Oy
O 11
O 12
S
S
S
“Intermediate Stop A Close Button”
Setting and nudging this stop same as “A Open”
C 12
S
Turn off all “B” intermediate stops (factory default) S+7+7 O # C 15 O ALL S
Enable “Intermediate Stop B” on the main channel
5
S+7+7 O # C 15 O 1 S
Enable “Int. Stop B” on 1
st
group channel
5
S+7+7 O # C 15 O 2 S
Enable “Int. Stop B” on 2
nd
group channel
5
S+7+7 O # C 15 O 3 S
Enable “Int. Stop B” on 3
rd
group channel
5
S+7+7 O # C 15 O 4 S
Enable “Int. Stop B” on 4
th
group channel
5
S+7+7 O # C 15 O 5 S
Enable “Int. Stop B” on 5
th
group channel
5
S+7+7 O # C 15 O 6 S
Enable “Int. Stop B” on 6
th
group channel
5
S+7+7 O # C 15 O 14 S
Enable “Int. Stop B” on the ALL channel
5
S+7+7 O # C 15 O 7 S
Enable “Int. Stop B” on Manual Switches
5
S+7+7 O # C 15 O 8 S
“Intermediate Stop B Open Button”
Setting and nudging this stop same as “A Open”
C 16
S
“Intermediate Stop B Close Button”
Setting and nudging this stop same as “A Open”
C 17
S
115VAC version: Set Minimum Load Threshold
Set to [(x+.1y).944] Amps
9
min = 0 0 (see notes), max = 4 1 (3.87A) use O10 for 0
Nudge this threshold .024A less sensitive (higher current)
Nudge this threshold .024A more sensitive (less current)
S+7+7
S+7+7
S+7+7
O #
O #
O #
C 18
C 18
C 18
Ox Oy
O 11
O 12
S
S
S
230VAC version: Set Minimum Load Threshold
Set to [(x+.1y).472] Amps
9
min = 0 0 (see notes), max = 4 1 (1.94A) use O10 for 0
Nudge this threshold .012A less sensitive (higher current)
Nudge this threshold .012A more sensitive (less current)
S+7+7
S+7+7
S+7+7
O #
O #
O #
C 18
C 18
C 18
Ox Oy
O 11
O 12
S
S
S
Set Stall Load Threshold
(same as above)
C 19
1
Sticky overrides Stop on Button Release if both are enabled