Installation/Operating Instructions
Access XL Electric Projection Screen by Draper
Copyright © 2013 Draper Inc. Form AccessXL_Inst13 Printed in U.S.A
Hanging Screen
When locating viewing surface and checking clearance for screen
operation, remember surface is centered in the length of the case. Regardless
of mounting method used, the following points apply:
1 Engage each ceiling mounting bracket with top of housing as shown below
and tighten nuts. The outer two brackets should be centered above the
location of the interior roller brackets (+/- 4"). The remaining two brackets
should be equally spaced between the outermost brackets.
2 Screen should be lifted into position only by the outermost ceiling
mounting brackets (those on ends). Keep case level by lifting each
end simultaneously to prevent surface damage. Never attempt to lift
screen along its length.
3 The entire weight of the unit MUST BE supported by the outermost
mounting brackets to provide a secure installation (those on ends). Do not
use intermediate brackets to lift or support the weight of the screen.
4 Screen should be positively and securely supported so that vibration or
even abusive pulling on viewing surface will not weaken installation.
5 Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Installer must also insure that
ceiling structure is of adequate strength. Supporting hardware (chains,
cables,
3
/
8
" rods, etc.) must be essentially vertical.
6 Entire bottom of case must be readily accessible after installation is
complete.
Electrical Connections
Screen operates on 110-120V, 60 Hz., with max 2.1 amp current draw.
Junction box is located just above the bottom access panel at left end of
screen (standard, right end may be specified). Remove the bottom access
panel for access to the junction box cover (see Bottom Access Panel Removal
instructions below). Remove four (4) hex head screws that secure the cover
to the junction box to expose the red, black, and white pigtail leads and the
green/yellow ground wire per wiring diagram on page 3.
If optional low voltage control or video interface control is specified and factory
installed, please refer to wiring diagrams on page 4.
Screen is shipped with internal wiring complete and control switch (es) fully
boxed. Wire to connect screen to switch (es) and switch (es) to power supply
should be furnished by installer. Connections must be made in accordance
with attached wiring diagram, and wiring must comply with national and
local electrical codes.
All operating switches should be “off before power is connected.
Bottom Access Panel Installation/Removal
Removal and replacement of the bottom closure panel requires two people
positioned about 5' from each end of the panel.
1 Before removing bottom closure, you must first remove screws at each
end of case and slide the closure clips inward, away from the outside of
the case (see Fig. 3).
®
If you encounter any difficulties installing or servicing your Access XL screen, call your
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Typical Installation
Alternate
Installation
(additional set of
brackets required
but not included).
Two intermediate
brackets must be
spaced evenly
from ends.
Slots along top of case
permit brackets to be
set at an angle
Case dimensions
on page 3.
Caution
1 Read instructions through completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions
invalidates warranty.
3 Pick up screen case from ends only. Picking case up at other points
will damage case and may damage fabric.
4 To insure a safe installation, the entire weight of the unit MUST BE
supported by outermost ceiling mounting brackets (those on ends).
Do not use intermediate brackets to lift or support the weight of
the screen.
5 To eliminate the possibility of the case warping, outermost
ceiling mounting brackets (those on ends) must be located cen-
tered above the interior roller mounting brackets (+/- 4").
6 Entire bottom of screen case should be unobstructed to permit access
to bottom panel for making electrical connections or servicing.
7 Screen should be installed level (using a carpenter’s level).
8 Operating switch(es) packed separately in screen carton. Do not
discard with packing material.
9 An appropriate disconnect device shall be provided as part of the
building installation.
Screen operates on 110-120V, 60 Hz., with max 2.1 amp current draw.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
7 Front, back and top of case must be straight—not forced to warp or bow
(see note 5 in caution box).
8 Do not use case to support adjacent sections of ceiling.
9 If case is painted on location, removal of roller/fabric assembly is
recommended prior to painting. If not removed, slot on bottom of case
should be shielded to protect viewing surface from paint splatters or
overspray.
Do not seal unit in ceiling until electrical connections have been made and
screen has been operated successfully.
Dowel
Shipping
Bracket
Shipping Brackets
If provided, remove shipping brackets by following Figure 2.
Figure 2
Series V
Closure
Case
Figure 3
Continued on next page
Front of case
removed for
clarity
Motor Type Duty Cycle
506S2PA, 510S2PA, 515S2PA, 1 minute on, 3 minutes off
506S2 ILT2, 515S2 ILT2
525A2PA, 535A2PA, 535A2 ILT2 1 minute on, 10 minutes off
NOTE: Excessive continuous operation may cause the motor to over
heat. If this happens the motor will shut off until it cools to a normal
operating temperature.
US Patent Nos. 6,137,629;
6,421,175; 6,532,109;
6,816,308; 7,559,707
7
/
8
" electrical cutout
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Seitenansicht 0
1 2 3 4 5

Inhaltsverzeichnis

Seite 1 - Continued on next page

Installation/Operating InstructionsAccess XL Electric Projection Screen by DraperCopyright © 2013 Draper Inc. Form AccessXL_Inst13 Printed in U.S.AH

Seite 2 - page 2 of 5

Accessory Access ACXLE & ACXLV Roller InstallationPlease note: When ordering a motor with built-in Low Voltage Controller, if the case ships separ

Seite 3 - page 3 of 5

Access XL Instructions by Draper page 3 of 5Limit Adjustments (Standard Motor)Please Note: Screen limits are factory set for optimum performance of t

Seite 4 - Case Dimensions

Access XL Instructions by Draper page 4 of 5Case Dimensions*These wiring diagrams are for Access XL screens with motor on audi-ence left (standard),

Seite 5 - RS232 with the MC1

Access XL Instructions by Draper page 5 of 5*These wiring diagrams are for Access XL screens with motor on audience left (standard), and fabric unrol

Kommentare zu diesen Handbüchern

Keine Kommentare