Draper SC1 Bedienerhandbuch Seite 112

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 120
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 111
Dimensions*
Colossal FlexShade by Draper
Page 2 of 2
Wiring Diagrams
Bottom Closure Removal/Replacement
Step 1
Step 2
Step 3
Step 4
Step 5
Removal and replacement of the bottom closure panel requires two people.
Closure should be handled as shown in Step 5 below to prevent bowing of the
closure during handling.
Screw and washer
Before removing bottom
closure, you must fi rst
remove brackets at each
end of case (see drawing
at right).
Internal Shade Wiring
White (Common)
Black
Red
Green (Ground)
Control
switch
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Red
Black
Black
To 110-120V Line
Dashed wiring by electrician
3
1
/
4
"
3
1
/
4
"
2
7
/
8
"
1"
3
/
8
" dia.
1
/
2
" dia.
2
7
/
8
"
2
7
/
8
"
Optional Wall Mounting Bracket
1
3
/4"
8"
2"
1
3
/8"
*
* - Case support brackets will be evenly spaced along the case
12"
13
1
/4"
2" 2"
2¼"
2¼"
*Please Note: Optional wall brackets add 1¾" per bracket to case
length. Wall mounting bracket hole location is 1" from end of
case.
www.draperinc.com
(765) 987-799
9
NOTE: Test shade operation. If shade direction does not
correspond with the switch orientation, turn power back off
and switch the red and black wires from the motor to the
switch.
Page 112 of 120
Seitenansicht 111

Kommentare zu diesen Handbüchern

Keine Kommentare