Seitenansicht 96
Motor Name:
506S1RH
RPM: 38
Volts: 230 Amps: .95
Min. Shade Width: 24” om
With Crank Override 29” om
Standard Motor Lead Length: 6’
Lead Type:
18-3 w/ground
Plug Options: Wago w or w/o wall plate
Anderson w or w/o wall plate
Limit Type: Push Button
Special Notes:
This is the standard motor for Draper’s 230V
Flexshade line. If you are pricing a shade, this
is the included motor in the pricing.
Installation Procedure:
1. Install brackets, endcaps, or box to mount shade
2. Test motor using a motor test cable and adjust
limits.
3. Let electrician connect to wiring
4. If control programming is required, then
program and set controls.
5. Test motors through wiring using switching
Controls that motor can wire into: Isolating Relays, SC1 controllers, GC4 control, SGC4 control,
SPGC4 control, Keyed Wall Switch, SP/DT toggle switch, DP/DT toggle switch, Animeo for questions
on other 230V controls ask Draper, Inc.
Used in: Flexshade, Lightbloc, Skylight
Hardware Only
Optional Lead Lengths: 12’ and 24’
Part No: C047.055
Product (s) Used In: Motorized Flexshades, Lightblocs,
and Skylights
Roller Diameter Choices: 2” aluminum, 2” steel,
2 1/8” steel, 3” steel, 3 1/8” steel
Parallel Wire:
No
Torque in Nm: 6
Page 97 of 120