Motor Name:
506S2ILTRH
RPM: 38
Volts: 120 Amps: .95
Min. Shade Width: 27 1/4” om
With Crank Override 32 1/4”
Standard Motor Lead Length: 6’
Lead Type:
18-2 w/ground
Limit Type: Remote Set
Special Notes:
This motor has built-in intelligence for
operation. It has both a data cable and high
voltage cable exiting the motor head. The
data cable ties into control and the high
voltage ties into power.
Installation Procedure:
1. Install brackets, endcaps, or box to mount shade
2. Test motor, set limits, and bind to controls
3. Let electrician connect to wiring
Controls that motor can wire into: This motor does not wire into any controls. It is controlled via
controllers that plug into the data cable existing the motor head.
Used in: Flexshade, Skylight, Lightbloc
Hardware Only
Plug Options: 3-prong
Optional Lead Lengths: 12’ and 24’
Part No: C047.162
Product (s) Used In: Motorized Flexshades, Lightblocs
Roller Diameter Choices: 2” aluminum, 2” steel,
2 1/8” steel, 3” steel, 3 1/8” steel
Parallel Wire:
Yes
Torque in Nm: 6