Draper SC1 Bedienerhandbuch Seite 45

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 120
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 44
IntelliFlex™ Inputs
®
We have many different low voltage input devices for controlling shades through
IntelliFlex. Here is a listing and brief description of each input available to you.
- IR control- This is an IR eye plugged in an SC1, SGC4, or SPGC4 to
receive IR remote commands.
- RF control- This is an RF receiver plugged in an SC1, SGC4, or SPGC4 to
receive RF remote commands. Long range antennas are available.
- IntelliFlex wall switch- This switch comes as a BUS version which plugs
directly into a SC1, SGC4, or SPGC4 or an RF version which talks to an
RF receiver. These versions of the switch are programmable to send out
whatever commands are desired. Dry contacts version which are not
programmable are also available for some types.
- RS 232 interface- This is an RS 232 bridge to run shades from RS 232
commands. These commands can give full function to the controls.
- Sun sensors- This is an interior sensor that will read light intensity and run
a group of shades up and down accordingly. It does not track the sun’ s
movement.
- Timer- This item will run a group of shades up and down at given times of
the day.
- Dry Contact Converter- This item takes dry contact commands and turns
them into bus commands for the SC1’s to respond.
- SolarFlex- This is a sun tracking software which is programmed to drive a
specifi c building’s shades per the needs of the end user based on the sun’s
position.
- Dry Contacts- The SC1, SGC4, and SPGC4 are built with dry contacts
already on them so one can connect dry contacts to one of the controls to
drive it. The dry contacts on the controller itself will not communicate on the
BUS line.
- Two-way communication on the bus line can be accomplished with certain
input set-ups and cabling. Ask Draper for more details.
ALL
OPEN CLOSE
OPEN CLOSE
STOP
1
2
3
4
5
6
7
8
9
10
11
12
ALL
OPEN CLOSE
OPEN CLOSE
STOP
1
2
3
4
5
6
7
8
9
10
11
12
R2D7 v2
Technology made simple
SYS 7 SYS 6 SYS 5 SYS 4
SYS 1 SYS 2 SYS 3 RS-232
MAIN
Wind
Input
Disable
Switch
Light
Sensor
Switch
EYE
BUS
RS232
PSSW
Red = Program Mode
Green = Visible Light
(Test Mode Only)
CAL
CLK PGM AUTO
RAND
MAN
OFF
AM
PM
MO TU WE TH FR
SA
SU ON
12:00 d
MODE
NEXT/
ON/
OFF
RESET
DAY/
DST
HOUR+
YEAR-
M+
ZONE-
YEAR-
IR control
RF control
IntelliFlex
wall switch
RS 232
interface
Sun
sensor
Timer
Dry Contact
Converter
Dry Contacts
Page 45 of 120