Please Note
Make sure power is disconnected before installing controls.
This product allows up to four motors to be connected to one motor control
or switch and provides group control of these motors. Make sure the total
FLA of all motors grouped together does not exceed the load carrying
capacity of the switch or motor control being used.
Up to 3 GC4s (12 motors total) can be banked as long as the switch ratings
are not exceeded and 80% of the circuit breaker rating is not exceeded.
GC4 enclosure is 8" x 8" x 4".
The Main Disconnect and Branch Circuit Protection shall be provided by
installer.
Maximum surrounding air temperature 70 degrees Celsius.
Use copper conductors rated 75 degrees celsius or higher only, 18-12AWG.
Please Note: This device has not been evaluated for reliability to the
Standard for Tests for Safety-Related Controls Employing Solid-State
Devices, UL 991 and therefore not considered suitable for entrapment
protection.
Electrical Specifi cations
Input:
Line Voltage: 115v AC +/- 10%
Output:
115VAC Largest Motor 1FLA, 4FLA Total
Wiring Instructions
GC4 Control by Draper
If you encounter any diffi culties installing/wiring your IntelliFlex control, call your
dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142.
Part Number C156.058
E258229
Inserting wire into spring terminal
Open spring terminal by inserting screw-
driver into upper opening.
Insert wire into lower opening.
Remove screwdriver.
Fabric un roll ing from back of
roller (standard)
Fabric unrolling from front of
roller (reverse roll)
Interior
side
Interior
side
Right hand motor
(Standard)
Black—Up
Red—Down
Left hand motor
Black—Down
Red—Up
Right hand motor
(Standard)
Red—Up
Black—Down
Left hand motor
Red—Down
Black—Up
White (Neutral)
White (Neutral)
Black (Up)
Black (Up)
Red (Down)
Red (Down)
Connect all
Motor
Grounds
Here
White (Neutral)
Black (Up)
Red (Down)
To
Motor
White
(Neutral)
Black (Up)
Red (Down)
To
Motor
White (Neutral)
Black (Up)
Red (Down)
To
Motor
White
(Neutral)
Black (Up)
Red (Down)
Ground
Ground
appropriately
Ground
Line
Neutral
Ground
Power
110-120v AC
White
Black
Red
Brown
Black
Black
Red
Brown
Ground
Connected
to Box
Switch
Note:
Motor red and black
wires will need to
"flip" if one motor
is right hand and the
other is left hand.
To
Motor
Connect all
Motor
Grounds
Here
Motors connect here
as in above diagram
Additional GC4
(if applicable)
Page 38 of 120