Motor Name:
510S2RH
RPM: 38
Volts: 120 Amps: 1.3
Min. Shade Width: 25” om
With Crank override 30” om
Standard Motor Lead Length: 6’
Lead Type:
18-3 w/ground
Limit Type: Push Button
Special Notes:
This motor is step up in power from the
standard motor. It is included in pricing
where needed.
Installation Procedure:
1. Install Brackets, endcaps, or box to mount shade
2. Test motor using a motor test cable and adjust
limits.
3. Let electrician connect to wiring
4. If control programming is required, then
program and set controls.
5. Test motors through wiring using switches
Controls that motor can wire into: Isolating Relays, SC1 controllers, GC4 control, SGC4 control,
SPGC4 control, Keyed Wall Switch, SP/DT toggle switch, DP/DT toggle switch, Animeo for questions
on other controls ask Draper, Inc.
Used in: Flexshade and Skylight
Hardware Only
Plug Options: Wago w or w/o wall plate
Anderson w or w/o wall plate
Optional Lead Lengths: 12’ and 24’
Part No: C047.056
Product (s) Used In: Motor Flexshades, Skylights as
needed
Roller Diameter Choices: 2” aluminum, 2” steel,
2 1/8” steel, 3” steel, 3 1/8” steel
Parallel Wire:
No
Torque in Nm: 10
Page 84 of 120